• Ckeditor/Images/2025-12-22/CDT6-2T双延时型时间继电器_目录抬头.png
  • Ckeditor/Images/2025-12-22/CDT6-2T双延时型时间继电器_目录抬头.png
CDT6-2T Dual Delay Type Time Relay

CDT6-2T

Feature
Dual-set power-on delay
Number of contacts
2 group switching
  • 3C
  • CE
Features of the CDT6-2T Series

■ 2 sets of power-on delay settings can be set separately 

■ Ultra-wide delay range, 0.1 seconds-10 days can be set (10 gears) 

■ It has AC/DC12V-240V ultra-wide operating voltage specifications to choose from 

■ The working status of the relay is indicated by an LED indicator 

■ Ultra-small size, only 18mm width, 35mm card rail installation 

■ The dual delay time relay can set 2 sets of power-on delay time,which can be used for time-sharing input of heavy loads toprevent

   the peak current of the main loop from being too large

■ 2 time relays can be replaced in specific applications to save costs

 

Selection Guide——Click to View
Various model combinations available. Click for the selection chart to find your exact specs.

 

General Parameters

Power terminal A1-A2
Rated supply voltage SuffixW: AC/DC 12-240 V (50-60 Hz SuffixM: AC 220 V (50-60 Hz)
Allowable fluctuation range of power supply -15%;+10%
Setting method knob
Delay range 0.1 s-10 days,Normally Open,Normally Closed
Setting accuracy 10%
Repeatability 0.2%
Temperature fluctuation error 0.05%℃,at=20 °C
10A Contact Ith: 10 A
16A Contact Ith: 16 A
Power indicator Green LED
Output relay indication Red LED
Mechanical durability 1×10⁷
Electrical durability (Resistive load) 1×10⁵
Operating ambient temperature -20 °C ~+55 °C
Storage and transportation ambient temperature -35 °C ~+75 °C
Installation method 35mm DIN rail mounting
Degree of protection IP20
Dimensions 90 mm×18 mm×65 mm

Specification

CDT6-2T
3C CE
Dual-set power-on delay
2 group switching

This product specification complies with global standards. However, regional specifications may vary slightly.

Contact Us

Contact the expert team to learn more about the product information.