CDA6 AC Current Monitoring Relay

CDA6-1

Feature
Overcurrent protection
Number of contacts
1 group
  • 3C
  • CE
Features of the CDA6 Series

■ The action delay time is adjustable from 0.1s to 10s to avoid peak current. 

■ The power-up delay time is adjustable from 0.1s to 10s to avoid the start-up current of the motor load. 

■ 6-speed current specifications are optional. 

■ Built-in isolated current transformer, and at the same time, an external current transformer can be connected to expand

   the monitoring current range. 

■ The working power supply voltage is AC 85-240V. 

■ The working status of the relay is indicated by an LED indicator. 

■ Ultra-small size, only 18mm width, 35mm card rail installation. 

 

Selection Guide——Click to View
Various model combinations available. Click for the selection chart to find your exact specs.

 

General Parameters

Power terminal A1-A2
Rated supply voltage AC85-240 V
Rated power frequency 50/60 Hz,0
Allowable fluctuation range of power supply -15%;+10%
Current setting range 0.05 A-0.5 A/0.1 A-1 A/0.2 A-2 A/0.5 A-5 A/0.8 A-8 A/1.6 A-16 A
Measuring current frequency AC50HZ
Maximum passing current 1 A/2 A/5 A/8 A/12 A/22 A
Setting method knob
Setting accuracy 10%
Action delay time 0.1 s ~ 10 s
Current measurement accuracy 5% (0.05-0.5 A: 10%)
Temperature fluctuation error <0.1%/℃
10A Contact Ith: 10 A
16A Contact Ith: 16 A
Power indicator Green LED
Output relay indication Red LED
Mechanical durability 1×10⁷
Electrical durability (Resistive load) 1×10⁵
Operating ambient temperature -20 °C ~+55 °C
Storage and transportation ambient temperature -35 °C ~+75 °C
Installation method 35mm DIN rail mounting
Degree of protection IP20
Dimensions 90 mm×18 mm×65 mm

Specification

CDA6-1
3C CE
Overcurrent protection
1 group
CDA6-2
3C CE
Undercurrent protection
2 groups

This product specification complies with global standards. However, regional specifications may vary slightly.

Contact Us